{"id":1363,"date":"2017-08-22T17:01:08","date_gmt":"2017-08-22T20:01:08","guid":{"rendered":"http:\/\/satya.com.br\/?page_id=1363"},"modified":"2017-09-04T13:42:05","modified_gmt":"2017-09-04T16:42:05","slug":"flux-bpl-2","status":"publish","type":"page","link":"https:\/\/satya.com.br\/?page_id=1363&lang=en","title":{"rendered":"Flux GLP"},"content":{"rendered":"<p lang=\"en-US\" align=\"justify\"><span style=\"color: #000000;\"><strong>Good Laboratory Practices (GLP)<\/strong> are a set of principles that ensure the reliability of the reports issued by a laboratory and are applied in studies related to the safe use of products for human health, plants, animal health and the environment. Laboratories recognized for adherence to the GLP principles have:<\/span><\/p>\n<ul>\n<li>\n<p lang=\"en-US\"><span style=\"color: #000000;\">Increased reliability, traceability and consistency<\/span><\/p>\n<\/li>\n<li>\n<p lang=\"en-US\"><span style=\"color: #000000;\">Participatory management<\/span><\/p>\n<\/li>\n<li>\n<p lang=\"en-US\"><span style=\"color: #000000;\">Quality warranty<\/span><\/p>\n<\/li>\n<li>\n<p lang=\"en-US\"><span style=\"color: #000000;\">Process management<\/span><\/p>\n<\/li>\n<li>\n<p lang=\"en-US\"><span style=\"color: #000000;\">Dissemination of information<\/span><\/p>\n<\/li>\n<li>\n<p lang=\"en-US\"><span style=\"color: #000000;\">Non-acceptance of errors<\/span><\/p>\n<\/li>\n<\/ul>\n<p lang=\"en-US\"><span style=\"color: #000000;\">Laboratories recognized for adherence to GLP principles besides having several benefits from a structured quality system are still well regarded by regulatory agencies.<\/span><\/p>\n<p><span style=\"color: #000000;\">The <\/span><strong><span style=\"color: #000000;\">Flux GLP<\/span><\/strong><span style=\"color: #000000;\">\u00a0system consists of six electronic data management forms conforming to GLP principles that are extended to several laboratories.<\/span><\/p>\n<p><span style=\"color: #000000;\">The forms that <span lang=\"en-US\">compose<\/span> <span lang=\"en-US\"><b>Flux GLP<\/b><\/span>\u00a0<span lang=\"en-US\">are:<\/span><\/span><\/p>\n<p><span style=\"color: #000000;\"><span lang=\"en-US\"><b>Equipment: <\/b><\/span><span lang=\"en-US\">It allows to register detailed information of each equipment, besides providing management information on maintenance, cleaning, calibration and uses among others.<\/span><\/span><\/p>\n<p><span style=\"color: #000000;\"><span lang=\"en-US\"><b>Teams and Responsibilities: <\/b><\/span><span lang=\"en-US\">It allows to register<\/span> <span lang=\"en-US\">information about the team involved in the job. In addition to the personal data information such as academic training, curriculum, roles and responsibilities, skills and qualification among others, may also be recorded.<br \/>\n<\/span><span lang=\"en-US\"><b><br \/>\nStandard Operating Procedures (SOP): <\/b><\/span><span lang=\"en-US\">It allows<\/span> <span lang=\"en-US\">the management of SOPs, allowing the entry of new documents and their approval. Authorized persons can manage records and reviews of these documents, which are saved in an easy-to-view history.<\/span><\/span><\/p>\n<p><span style=\"color: #000000;\"><span lang=\"en-US\"><b>Test and Reference Substances: <\/b><\/span><span lang=\"en-US\">It allows<\/span> <span lang=\"en-US\">the management of test and reference substances. Records are maintained including substance characterization, date of receipt, storage and use among others.<\/span><\/span><\/p>\n<p><span style=\"color: #000000;\"><span lang=\"en-US\"><b>Study Plan: <\/b><\/span><span lang=\"en-US\">It allows the storage of information that must be inserted before, during and after a study. Information about dates, sponsor, methods, experiment sites, results, changes (deviations and menus), and final evaluation among others, can be stored.<\/span><\/span><\/p>\n<p><span style=\"color: #000000;\"><span lang=\"en-US\"><b>System Test:<\/b><\/span> <span lang=\"en-US\">It allows the management of information about the system used for the tests, be it animal, plant or other cellular, subcellular, chemical or physical system or the combination of these, which are defined as object of study. Records of origin, conditions, and date of arrival at the laboratory are maintained among others.<\/span><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-1567 aligncenter\" src=\"http:\/\/satya.com.br\/wp-content\/uploads\/2017\/08\/bpl-equipamentos-1-300x154.png\" alt=\"\" width=\"642\" height=\"331\" srcset=\"https:\/\/satya.com.br\/wp-content\/uploads\/2017\/08\/bpl-equipamentos-1-300x154.png 300w, https:\/\/satya.com.br\/wp-content\/uploads\/2017\/08\/bpl-equipamentos-1-768x395.png 768w, https:\/\/satya.com.br\/wp-content\/uploads\/2017\/08\/bpl-equipamentos-1-1024x526.png 1024w, https:\/\/satya.com.br\/wp-content\/uploads\/2017\/08\/bpl-equipamentos-1.png 1288w\" sizes=\"(max-width: 642px) 100vw, 642px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" class=\"wp-image-1568 aligncenter\" src=\"http:\/\/satya.com.br\/wp-content\/uploads\/2017\/08\/bpl-equipamentos-2-1-300x155.png\" alt=\"\" width=\"634\" height=\"328\" srcset=\"https:\/\/satya.com.br\/wp-content\/uploads\/2017\/08\/bpl-equipamentos-2-1-300x155.png 300w, https:\/\/satya.com.br\/wp-content\/uploads\/2017\/08\/bpl-equipamentos-2-1-768x397.png 768w, https:\/\/satya.com.br\/wp-content\/uploads\/2017\/08\/bpl-equipamentos-2-1-1024x529.png 1024w, https:\/\/satya.com.br\/wp-content\/uploads\/2017\/08\/bpl-equipamentos-2-1.png 1291w\" sizes=\"(max-width: 634px) 100vw, 634px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"Good Laboratory Practices (GLP) are a set of principles that ensure the reliability of the reports issued by a laboratory and are applied in studies related to the safe use of products for human health, plants, animal health and the environment. Laboratories recognized for adherence to the GLP principles have: Increased reliability, traceability and consistency","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1363","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/satya.com.br\/index.php?rest_route=\/wp\/v2\/pages\/1363","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/satya.com.br\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/satya.com.br\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/satya.com.br\/index.php?rest_route=\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/satya.com.br\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1363"}],"version-history":[{"count":14,"href":"https:\/\/satya.com.br\/index.php?rest_route=\/wp\/v2\/pages\/1363\/revisions"}],"predecessor-version":[{"id":1569,"href":"https:\/\/satya.com.br\/index.php?rest_route=\/wp\/v2\/pages\/1363\/revisions\/1569"}],"wp:attachment":[{"href":"https:\/\/satya.com.br\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1363"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}